MODINE 307952

MODINE PDP Series 43712 Power Vented Gas Fired Propeller Heater, 115 V, 4.05 A, 150000 Btu/hr BTU, 1 ph-Phase

Manufacturer: Modine Mfg Co
Brand: MODINE
Part #: 307952
MPN: 43712
Customer Part #:
Min. Order Qty: 1
Login for Availability
Login for Price
AFUE Rating      :      80 %
Amperage Rating      :      4.05 A
BTU Rating      :      150000 Btu/hr
CFM Rating      :      2180 cfm
Connection Size      :      1/2 in
Connection Type      :      NPT
Dimensions      :      21 in L x 22 in W x 35-1/4 in H
Drive Type      :      Direct
Efficiency      :      80 %
Frequency Rating      :      50 Hz
Fuel Type      :      Natural Gas
HP Rating      :      1/8 hp
Heat Throw      :      55 ft
Ignition Type      :      Direct Spark
Motor Type      :      PSC
Mounting Height      :      16 ft
Number of Stages      :      1
Phase      :      1 ph
Series      :      PDP Series
Temperature Rating      :      51 deg F
Voltage Rating      :      115 V

The perfect way to efficiently heat an ample space such as a large pole barn or a commercial or industrial warehouse. Easy to use and time tested for quality and durability. The PDP model series expands on the size range of the Hot Dawg Series. Our commercial-grade power vent unit heaters come with either a propeller fan or centrifugal blower fan in seven different sizes.

MODINE Power Vented Gas Fired Propeller Heater, Series: PDP Series, 150000 Btu/hr, 115 V, 4.05 A, 2180 cfm CFM Rating, 1/8 hp HP Rating, 80 % AFUE, 1 ph, 50 Hz, NPT, 1/2 in, Natural Gas, 80 % Efficiency, PSC Motor, Direct Spark Ignition, Direct Drive, 1 Stage, 16 ft Mounting Height, 55 ft Heat Throw, 51 deg F, 21 in L x 22 in W x 35-1/4 in H

  • 83% thermal efficiency, maximizing seasonal efficiency through the use of a collector box and the power exhauster
  • A power exhaust can rotate 180° allowing the unit to be vented vertically or horizontally
  • A 100% shut-off if the unit does not light, to ensure that unburned gases do not build up in the unit
  • An intermittent pilot-ignition system with continuous retry to keep the unit from locking and needing to be rest if the unit does not light on the first try
  • All PDP/BDP units to be field-converted from natural gas to propane if desired
  • A safety pressure switch monitors the vent pipe to assure flue gases leave the building and do not back up in the space
  • Designed to utilize the smallest diameter vent pipe possible
  • Wing screws so that the bottom pan can be dropped without a screwdriver or nut driver
  • A level hanging mechanism for easy field adjustments after adding accessories that may change the unit center of gravity

back To Top